Compare JVA’s electric fence energisers to see which energiser will suit your fencing set up best.
JVA Electric Fence Energiser Specifications |
||||||||||
Model (links to product page) |
Energizer output voltage # | Stored Energy | Power | ~12V drain | *Solar Panel Size for Minimum Expected Sun Hours Per Day | *Solar
Battery |
Peak Output | |||
3hrs |
4hrs | 5hrs |
>6hrs |
|||||||
M1.5 | 8.0kV | 1.6J | 230Vac | – | – | – | – | – | – |
1.5J |
M3 |
8.0kV | 3.3J | 230Vac | – | – | – | – | – | – | 3.0J |
8.2kV | 2.1J | 12Vdc^ | 165mA | 30W | 20W | 20W | 15W | 26Ah |
1.5J |
|
MB3 | 8.5kV | 4.2J | 12Vdc^ | 300mA | 40W | 30W | 25W | 20W | 40Ah |
3.0J |
8.8kV | 6.3J | 12Vdc ^ | 490mA | 85W | 60W | 40W | 40W | 65Ah |
4.5J |
|
MB8 | 8.2kV | 12J | 12 to 24Vdc^ | 0.9A | 150W | 120W | 100W | 85W | 150Ah |
8J |
8.2kV | 18J | 12 to 24Vdc^ | 1.25A | 180W | 150W | 120W | 100W | 200Ah |
12J |
|
8.2kV | 24J | 12 to 24Vdc^ | 1.6A | 220W | 180W | 150W | 120W | 260Ah |
16J |
|
9.2kV | 0.1J | 12Vdc | 14mA | 2W | 2W | 2W | 2W | – |
0.08J |
|
6.4kV | 0.14J | solar | – | – | – | – | – | – |
0.1J |
|
7.5kV | 0.7J | solar | – | – | – | – | – | – |
0.5J |
|
7.5kV | 1.1J | solar | – | – | – | – | – | – |
0.8J |
#No load, actual voltage on a short fence can be as high as 10kV
*Minimum recommended sizes for 5 consecutive days of overcast weather.
^The energizer can also be powered from 240Vac by using the external power pack supplied with the energizer.
~Current drain rating is for a 12V power source. Current drain will vary with voltage.